The battery charging Cautions
1 Charge
Must have a constant current and constant voltage, in order to fully charged battery charging
The charging current must be less than 2C5A / battery
The charging voltage should not exceed 4.3V / battery
2. Discharge
Lithium battery pack
The discharge current must be less than to 2C5A / battery.
The discharge temperature range of -20-60 ° C
Discharge termination voltage of 2.75V / battery
3 necessary to protect the line
Should meet the following requirements in order to ensure safety.
Charger and protection circuit
Charger terminal voltage requirements at 4.200 ± 0.049V; overcharge detection voltage requirements of 4.25 ± 0.020V; overcharge release voltage requirements of rechargeable batteries Road should meet the following requirements
Charger terminal voltage requirements at 4.200 ± 0.049V; overcharge detection voltage requirements of 4.25 ± 0.020V; overcharge release voltage requirements in 4.15 ± 0.050V; discharge terminal voltage of 3.00 ± 0.10V; over discharge detection voltage of 2.7 ± 0.08V; overdischarge release voltage 3.0 ± 0.01V; the requirements of the current detection value 3.0 ± 1.0A
4. Note
Battery pack precautions
Lithium batteries, such as of TA1, TA2), in order to prevent abnormal leaving the battery due to equipment failure. Protective equipment must be set to the appropriate position with the battery, so that the protective equipment to get the exact temperature of the battery.